Print this page
8074 need to add FMA event for SSD wearout
   1 #
   2 # Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.

   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #


  87 msgid "DISK-8000-3E.impact"
  88 msgstr "The device has failed. The service may have been lost or degraded.\n"
  89 msgid "DISK-8000-3E.action"
  90 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
  91 #
  92 # code: DISK-8000-4Q
  93 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr
  94 #
  95 msgid "DISK-8000-4Q.type"
  96 msgstr "Fault"
  97 msgid "DISK-8000-4Q.severity"
  98 msgstr "Critical"
  99 msgid "DISK-8000-4Q.description"
 100 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
 101 msgid "DISK-8000-4Q.response"
 102 msgstr "The device may be offlined or degraded.\n"
 103 msgid "DISK-8000-4Q.impact"
 104 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
 105 msgid "DISK-8000-4Q.action"
 106 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
















   1 #
   2 # Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 # Copyright 2016 Nexenta Systems, Inc.  All rights reserved.
   5 #
   6 # CDDL HEADER START
   7 #
   8 # The contents of this file are subject to the terms of the
   9 # Common Development and Distribution License (the "License").
  10 # You may not use this file except in compliance with the License.
  11 #
  12 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  13 # or http://www.opensolaris.org/os/licensing.
  14 # See the License for the specific language governing permissions
  15 # and limitations under the License.
  16 #
  17 # When distributing Covered Code, include this CDDL HEADER in each
  18 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  19 # If applicable, add the following below this CDDL HEADER, with the
  20 # fields enclosed by brackets "[]" replaced with your own identifying
  21 # information: Portions Copyright [yyyy] [name of copyright owner]
  22 #
  23 # CDDL HEADER END
  24 #


  88 msgid "DISK-8000-3E.impact"
  89 msgstr "The device has failed. The service may have been lost or degraded.\n"
  90 msgid "DISK-8000-3E.action"
  91 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
  92 #
  93 # code: DISK-8000-4Q
  94 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr
  95 #
  96 msgid "DISK-8000-4Q.type"
  97 msgstr "Fault"
  98 msgid "DISK-8000-4Q.severity"
  99 msgstr "Critical"
 100 msgid "DISK-8000-4Q.description"
 101 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
 102 msgid "DISK-8000-4Q.response"
 103 msgstr "The device may be offlined or degraded.\n"
 104 msgid "DISK-8000-4Q.impact"
 105 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
 106 msgid "DISK-8000-4Q.action"
 107 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
 108 #
 109 # code: DISK-8000-8D
 110 # keys: fault.io.disk.ssm-wearout
 111 #
 112 msgid "DISK-8000-8D.type"
 113 msgstr "Fault"
 114 msgid "DISK-8000-8D.severity"
 115 msgstr "Major"
 116 msgid "DISK-8000-8D.description"
 117 msgstr "A solid state media device is nearing end of life as projected by the manufacturer."
 118 msgid "DISK-8000-8D.response"
 119 msgstr "None."
 120 msgid "DISK-8000-8D.impact"
 121 msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss."
 122 msgid "DISK-8000-8D.action"
 123 msgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive."