1 # 2 # Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3 # Use is subject to license terms. 4 # Copyright 2016 Nexenta Systems, Inc. All rights reserved. 5 # 6 # CDDL HEADER START 7 # 8 # The contents of this file are subject to the terms of the 9 # Common Development and Distribution License (the "License"). 10 # You may not use this file except in compliance with the License. 11 # 12 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 13 # or http://www.opensolaris.org/os/licensing. 14 # See the License for the specific language governing permissions 15 # and limitations under the License. 16 # 17 # When distributing Covered Code, include this CDDL HEADER in each 18 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 19 # If applicable, add the following below this CDDL HEADER, with the 20 # fields enclosed by brackets "[]" replaced with your own identifying 21 # information: Portions Copyright [yyyy] [name of copyright owner] 22 # 23 # CDDL HEADER END 24 # 25 # 26 # DO NOT EDIT -- this file is generated by the Event Registry. 27 # 28 # 29 # code: DISK-8000-0X 30 # keys: fault.io.disk.predictive-failure 31 # 32 msgid "DISK-8000-0X.type" 33 msgstr "Fault" 34 msgid "DISK-8000-0X.severity" 35 msgstr "Major" 36 msgid "DISK-8000-0X.description" 37 msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 38 msgid "DISK-8000-0X.response" 39 msgstr "None.\n" 40 msgid "DISK-8000-0X.impact" 41 msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 42 msgid "DISK-8000-0X.action" 43 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 44 # 45 # code: DISK-8000-12 46 # keys: fault.io.disk.over-temperature 47 # 48 msgid "DISK-8000-12.type" 49 msgstr "Fault" 50 msgid "DISK-8000-12.severity" 51 msgstr "Major" 52 msgid "DISK-8000-12.description" 53 msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 54 msgid "DISK-8000-12.response" 55 msgstr "None.\n" 56 msgid "DISK-8000-12.impact" 57 msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 58 msgid "DISK-8000-12.action" 59 msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 60 # 61 # code: DISK-8000-2J 62 # keys: fault.io.disk.self-test-failure 63 # 64 msgid "DISK-8000-2J.type" 65 msgstr "Fault" 66 msgid "DISK-8000-2J.severity" 67 msgstr "Critical" 68 msgid "DISK-8000-2J.description" 69 msgstr "One or more disk self tests failed.\n Refer to %s for more information." 70 msgid "DISK-8000-2J.response" 71 msgstr "None.\n" 72 msgid "DISK-8000-2J.impact" 73 msgstr "The disk has failed.\n" 74 msgid "DISK-8000-2J.action" 75 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 76 # 77 # code: DISK-8000-3E 78 # keys: fault.io.scsi.cmd.disk.dev.rqs.derr 79 # 80 msgid "DISK-8000-3E.type" 81 msgstr "Fault" 82 msgid "DISK-8000-3E.severity" 83 msgstr "Critical" 84 msgid "DISK-8000-3E.description" 85 msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." 86 msgid "DISK-8000-3E.response" 87 msgstr "The device may be offlined or degraded.\n" 88 msgid "DISK-8000-3E.impact" 89 msgstr "The device has failed. The service may have been lost or degraded.\n" 90 msgid "DISK-8000-3E.action" 91 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" 92 # 93 # code: DISK-8000-4Q 94 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr 95 # 96 msgid "DISK-8000-4Q.type" 97 msgstr "Fault" 98 msgid "DISK-8000-4Q.severity" 99 msgstr "Critical" 100 msgid "DISK-8000-4Q.description" 101 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." 102 msgid "DISK-8000-4Q.response" 103 msgstr "The device may be offlined or degraded.\n" 104 msgid "DISK-8000-4Q.impact" 105 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" 106 msgid "DISK-8000-4Q.action" 107 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n" 108 # 109 # code: DISK-8000-8D 110 # keys: fault.io.disk.ssm-wearout 111 # 112 msgid "DISK-8000-8D.type" 113 msgstr "Fault" 114 msgid "DISK-8000-8D.severity" 115 msgstr "Major" 116 msgid "DISK-8000-8D.description" 117 msgstr "A solid state media device is nearing end of life as projected by the manufacturer." 118 msgid "DISK-8000-8D.response" 119 msgstr "None." 120 msgid "DISK-8000-8D.impact" 121 msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss." 122 msgid "DISK-8000-8D.action" 123 msgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive."