1 #
   2 # Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 # Copyright 2016 Nexenta Systems, Inc.  All rights reserved.
   5 #
   6 # CDDL HEADER START
   7 #
   8 # The contents of this file are subject to the terms of the
   9 # Common Development and Distribution License (the "License").
  10 # You may not use this file except in compliance with the License.
  11 #
  12 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  13 # or http://www.opensolaris.org/os/licensing.
  14 # See the License for the specific language governing permissions
  15 # and limitations under the License.
  16 #
  17 # When distributing Covered Code, include this CDDL HEADER in each
  18 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  19 # If applicable, add the following below this CDDL HEADER, with the
  20 # fields enclosed by brackets "[]" replaced with your own identifying
  21 # information: Portions Copyright [yyyy] [name of copyright owner]
  22 #
  23 # CDDL HEADER END
  24 #
  25 #
  26 # DO NOT EDIT -- this file is generated by the Event Registry.
  27 #
  28 #
  29 # code: DISK-8000-0X
  30 # keys: fault.io.disk.predictive-failure
  31 #
  32 msgid "DISK-8000-0X.type"
  33 msgstr "Fault"
  34 msgid "DISK-8000-0X.severity"
  35 msgstr "Major"
  36 msgid "DISK-8000-0X.description"
  37 msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
  38 msgid "DISK-8000-0X.response"
  39 msgstr "None.\n"
  40 msgid "DISK-8000-0X.impact"
  41 msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
  42 msgid "DISK-8000-0X.action"
  43 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
  44 #
  45 # code: DISK-8000-12
  46 # keys: fault.io.disk.over-temperature
  47 #
  48 msgid "DISK-8000-12.type"
  49 msgstr "Fault"
  50 msgid "DISK-8000-12.severity"
  51 msgstr "Major"
  52 msgid "DISK-8000-12.description"
  53 msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
  54 msgid "DISK-8000-12.response"
  55 msgstr "None.\n"
  56 msgid "DISK-8000-12.impact"
  57 msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
  58 msgid "DISK-8000-12.action"
  59 msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
  60 #
  61 # code: DISK-8000-2J
  62 # keys: fault.io.disk.self-test-failure
  63 #
  64 msgid "DISK-8000-2J.type"
  65 msgstr "Fault"
  66 msgid "DISK-8000-2J.severity"
  67 msgstr "Critical"
  68 msgid "DISK-8000-2J.description"
  69 msgstr "One or more disk self tests failed.\n  Refer to %s for more information."
  70 msgid "DISK-8000-2J.response"
  71 msgstr "None.\n"
  72 msgid "DISK-8000-2J.impact"
  73 msgstr "The disk has failed.\n"
  74 msgid "DISK-8000-2J.action"
  75 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
  76 #
  77 # code: DISK-8000-3E
  78 # keys: fault.io.scsi.cmd.disk.dev.rqs.derr
  79 #
  80 msgid "DISK-8000-3E.type"
  81 msgstr "Fault"
  82 msgid "DISK-8000-3E.severity"
  83 msgstr "Critical"
  84 msgid "DISK-8000-3E.description"
  85 msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
  86 msgid "DISK-8000-3E.response"
  87 msgstr "The device may be offlined or degraded.\n"
  88 msgid "DISK-8000-3E.impact"
  89 msgstr "The device has failed. The service may have been lost or degraded.\n"
  90 msgid "DISK-8000-3E.action"
  91 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
  92 #
  93 # code: DISK-8000-4Q
  94 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr
  95 #
  96 msgid "DISK-8000-4Q.type"
  97 msgstr "Fault"
  98 msgid "DISK-8000-4Q.severity"
  99 msgstr "Critical"
 100 msgid "DISK-8000-4Q.description"
 101 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
 102 msgid "DISK-8000-4Q.response"
 103 msgstr "The device may be offlined or degraded.\n"
 104 msgid "DISK-8000-4Q.impact"
 105 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
 106 msgid "DISK-8000-4Q.action"
 107 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
 108 #
 109 # code: DISK-8000-8D
 110 # keys: fault.io.disk.ssm-wearout
 111 #
 112 msgid "DISK-8000-8D.type"
 113 msgstr "Fault"
 114 msgid "DISK-8000-8D.severity"
 115 msgstr "Major"
 116 msgid "DISK-8000-8D.description"
 117 msgstr "A solid state media device is nearing end of life as projected by the manufacturer."
 118 msgid "DISK-8000-8D.response"
 119 msgstr "None."
 120 msgid "DISK-8000-8D.impact"
 121 msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss."
 122 msgid "DISK-8000-8D.action"
 123 msgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive."