1 #
   2 # Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
   3 # Use is subject to license terms.
   4 #
   5 # CDDL HEADER START
   6 #
   7 # The contents of this file are subject to the terms of the
   8 # Common Development and Distribution License (the "License").
   9 # You may not use this file except in compliance with the License.
  10 #
  11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
  12 # or http://www.opensolaris.org/os/licensing.
  13 # See the License for the specific language governing permissions
  14 # and limitations under the License.
  15 #
  16 # When distributing Covered Code, include this CDDL HEADER in each
  17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
  18 # If applicable, add the following below this CDDL HEADER, with the
  19 # fields enclosed by brackets "[]" replaced with your own identifying
  20 # information: Portions Copyright [yyyy] [name of copyright owner]
  21 #
  22 # CDDL HEADER END
  23 #
  24 #
  25 # DO NOT EDIT -- this file is generated by the Event Registry.
  26 #
  27 #
  28 # code: DISK-8000-0X
  29 # keys: fault.io.disk.predictive-failure
  30 #
  31 msgid "DISK-8000-0X.type"
  32 msgstr "Fault"
  33 msgid "DISK-8000-0X.severity"
  34 msgstr "Major"
  35 msgid "DISK-8000-0X.description"
  36 msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
  37 msgid "DISK-8000-0X.response"
  38 msgstr "None.\n"
  39 msgid "DISK-8000-0X.impact"
  40 msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
  41 msgid "DISK-8000-0X.action"
  42 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
  43 #
  44 # code: DISK-8000-12
  45 # keys: fault.io.disk.over-temperature
  46 #
  47 msgid "DISK-8000-12.type"
  48 msgstr "Fault"
  49 msgid "DISK-8000-12.severity"
  50 msgstr "Major"
  51 msgid "DISK-8000-12.description"
  52 msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
  53 msgid "DISK-8000-12.response"
  54 msgstr "None.\n"
  55 msgid "DISK-8000-12.impact"
  56 msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
  57 msgid "DISK-8000-12.action"
  58 msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
  59 #
  60 # code: DISK-8000-2J
  61 # keys: fault.io.disk.self-test-failure
  62 #
  63 msgid "DISK-8000-2J.type"
  64 msgstr "Fault"
  65 msgid "DISK-8000-2J.severity"
  66 msgstr "Critical"
  67 msgid "DISK-8000-2J.description"
  68 msgstr "One or more disk self tests failed.\n  Refer to %s for more information."
  69 msgid "DISK-8000-2J.response"
  70 msgstr "None.\n"
  71 msgid "DISK-8000-2J.impact"
  72 msgstr "The disk has failed.\n"
  73 msgid "DISK-8000-2J.action"
  74 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
  75 #
  76 # code: DISK-8000-3E
  77 # keys: fault.io.scsi.cmd.disk.dev.rqs.derr
  78 #
  79 msgid "DISK-8000-3E.type"
  80 msgstr "Fault"
  81 msgid "DISK-8000-3E.severity"
  82 msgstr "Critical"
  83 msgid "DISK-8000-3E.description"
  84 msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
  85 msgid "DISK-8000-3E.response"
  86 msgstr "The device may be offlined or degraded.\n"
  87 msgid "DISK-8000-3E.impact"
  88 msgstr "The device has failed. The service may have been lost or degraded.\n"
  89 msgid "DISK-8000-3E.action"
  90 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
  91 #
  92 # code: DISK-8000-4Q
  93 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr
  94 #
  95 msgid "DISK-8000-4Q.type"
  96 msgstr "Fault"
  97 msgid "DISK-8000-4Q.severity"
  98 msgstr "Critical"
  99 msgid "DISK-8000-4Q.description"
 100 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
 101 msgid "DISK-8000-4Q.response"
 102 msgstr "The device may be offlined or degraded.\n"
 103 msgid "DISK-8000-4Q.impact"
 104 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
 105 msgid "DISK-8000-4Q.action"
 106 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"