1 # 2 # Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3 # Use is subject to license terms. 4 # 5 # CDDL HEADER START 6 # 7 # The contents of this file are subject to the terms of the 8 # Common Development and Distribution License (the "License"). 9 # You may not use this file except in compliance with the License. 10 # 11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12 # or http://www.opensolaris.org/os/licensing. 13 # See the License for the specific language governing permissions 14 # and limitations under the License. 15 # 16 # When distributing Covered Code, include this CDDL HEADER in each 17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18 # If applicable, add the following below this CDDL HEADER, with the 19 # fields enclosed by brackets "[]" replaced with your own identifying 20 # information: Portions Copyright [yyyy] [name of copyright owner] 21 # 22 # CDDL HEADER END 23 # 24 # 25 # DO NOT EDIT -- this file is generated by the Event Registry. 26 # 27 # 28 # code: DISK-8000-0X 29 # keys: fault.io.disk.predictive-failure 30 # 31 msgid "DISK-8000-0X.type" 32 msgstr "Fault" 33 msgid "DISK-8000-0X.severity" 34 msgstr "Major" 35 msgid "DISK-8000-0X.description" 36 msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 37 msgid "DISK-8000-0X.response" 38 msgstr "None.\n" 39 msgid "DISK-8000-0X.impact" 40 msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 41 msgid "DISK-8000-0X.action" 42 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 43 # 44 # code: DISK-8000-12 45 # keys: fault.io.disk.over-temperature 46 # 47 msgid "DISK-8000-12.type" 48 msgstr "Fault" 49 msgid "DISK-8000-12.severity" 50 msgstr "Major" 51 msgid "DISK-8000-12.description" 52 msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 53 msgid "DISK-8000-12.response" 54 msgstr "None.\n" 55 msgid "DISK-8000-12.impact" 56 msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 57 msgid "DISK-8000-12.action" 58 msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 59 # 60 # code: DISK-8000-2J 61 # keys: fault.io.disk.self-test-failure 62 # 63 msgid "DISK-8000-2J.type" 64 msgstr "Fault" 65 msgid "DISK-8000-2J.severity" 66 msgstr "Critical" 67 msgid "DISK-8000-2J.description" 68 msgstr "One or more disk self tests failed.\n Refer to %s for more information." 69 msgid "DISK-8000-2J.response" 70 msgstr "None.\n" 71 msgid "DISK-8000-2J.impact" 72 msgstr "The disk has failed.\n" 73 msgid "DISK-8000-2J.action" 74 msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 75 # 76 # code: DISK-8000-3E 77 # keys: fault.io.scsi.cmd.disk.dev.rqs.derr 78 # 79 msgid "DISK-8000-3E.type" 80 msgstr "Fault" 81 msgid "DISK-8000-3E.severity" 82 msgstr "Critical" 83 msgid "DISK-8000-3E.description" 84 msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." 85 msgid "DISK-8000-3E.response" 86 msgstr "The device may be offlined or degraded.\n" 87 msgid "DISK-8000-3E.impact" 88 msgstr "The device has failed. The service may have been lost or degraded.\n" 89 msgid "DISK-8000-3E.action" 90 msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" 91 # 92 # code: DISK-8000-4Q 93 # keys: fault.io.scsi.cmd.disk.dev.rqs.merr 94 # 95 msgid "DISK-8000-4Q.type" 96 msgstr "Fault" 97 msgid "DISK-8000-4Q.severity" 98 msgstr "Critical" 99 msgid "DISK-8000-4Q.description" 100 msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." 101 msgid "DISK-8000-4Q.response" 102 msgstr "The device may be offlined or degraded.\n" 103 msgid "DISK-8000-4Q.impact" 104 msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" 105 msgid "DISK-8000-4Q.action" 106 msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"